Xinde Laser Chiller Anti-freeze Reference
Dear Xinde Laser User:
Hello! Thank you for choosing Xinde Laser. As the severe winter arrives, we kindly remind you:
It is time to add antifreeze to the water circuit of your chiller!
Freezing can damage the compressor and water pump inside the chiller, as well as the water and optical paths of the laser, fiber head and welding head, causing you huge losses. Please take
proper anti-freeze measures.
Details are as follows:
1. Add antifreeze (automotive antifreeze is prohibited)
1.1 Power off the chiller and open the drain port to empty the water;
1.2 Pour ethylene glycol and cooling water into the same container in the proportions shown in the table below;

1.3 Stir the two solutions in the container evenly;
1.4 Fill the prepared solution into the chiller water tank, then power on and let the water circulate until the liquid level meets the requirement;
2. Chiller Keeps Power On
2.1 Ensure the chiller filter and deionized water are clean;
2.2 Keep the equipment power on and the chiller running normally;
WARNING!!
Once the equipment is powered off, experiences a power outage, or the chiller alarms, the cooling water stops circulating and the equipment will freeze. Therefore, the power-on method should be used with caution and only in emergencies.
3. If the equipment will not be used for more than 2 days, please drain the water circuit.
3.1 Open the chiller drain valve and empty the tank. If there are deionized cartridges and filters (old chiller models), remove them as well;
3.2 Remove the four water lines of the main circuit and the external optical path;
3.3 Use clean compressed air or nitrogen at 0.5 MPa (5 kg) to blow air into the main circuit outlet. Blow for 3 minutes, stop for 1 minute, and repeat 4-5 times. Observe the change in the water mist at the drain outlet; when
the drain outlet shows no water mist at all, the chiller draining procedure is complete.